Product Details
24v 100amp rectifier plating equipment with auto timer and ampere hour function, which exported to Portugal.
Plating rectifier parameters:
Input voltage |
220V/380/415V/460V AC ±10% 3 phase 4/5 line, 50-60Hz |
Rated output voltage |
5000A |
Rated output current |
5V/12V |
Output range |
0-100% |
Control Accuracy |
≤0.5% |
Power factor |
≥0.94 |
Efficiency |
typical 90% at rated output |
Current ripple |
<5% at rated output,low ripple in whole range |
Control mode |
constant current/constant voltage |
Cooling |
Air cooling or water cooling |
Protection class |
IP32 for Air cooling,IP44 for Water cooling |
Insulation grade |
B |
HMI |
Touch Panel on control box |
Remote control interface |
Standard RS485, Profibus, Profinet, 0-10V/4-20mA available |
Alarm type |
Audible and visual alarm |
Protections
|
Output overcurrent protection |
Over heat protection |
IGBT Driving protection |
Features
|
Digital DSP control(USA TI DSP Chip) |
History date record function |
Waveform function |
History protection record function |
Waveform function |
History protection record function |
Ambient temp |
Max. 40℃, derated operation up to 50℃ |
Altitude |
≤2000m altitude. De-rated operation if higher |
Clients’ feedback:
Welcome your inquiry:
wechat:13669532124
Tel/whatsapp:18390828699
http://www.haneyinternational.com/